Trough / Tank Installation:
Flush pipe lines into water tank or troughs before installing Fast~Flo Valve into
new system

Isolate the water going to the trough or tank to replace valve in an existing system.

Thread O-Ring end of correct size Long Tail Adaptor into Fast~Flo Valve Body and tighten firmly enough that the O-Ring creates a seal against the Fast~Flo Valve Body face. Do not over tighten.
 
Fast~Flo Side Entry   Fast~Flo Top Entry
TO CHANGE WATER LEVEL
Adjust length of cord at top of float. Use the nut & cord on the long arm valve only.
 
Side Entry Trough/Tank:
Place the ribbed side of the Rubber (soft) Washer against the hole inside the trough/tank. Insert the Long Tail Adaptor through the washer & inlet hole in the trough/tank wall.

On the outside, place the Poly (hard) Washer on the Long Tail Adaptor with the ribs facing the trough/tank wall. Thread on Adaptor Nut and tighten firmly. Do not over tighten.

Screw the Cord Nut* onto the Fast~Flo Brass arm.

Thread the Cord* through the Fast~Flo Float. Tie the Cord off to achieve the correct water level.

  *Cord and Nuts only supplied with long arm version.
 
NOTE: If there is an existing or moulded
threaded inlet in the trough or tank use a
Hansen Standard Adaptor.
 
Top Entry Trough/Tank
Place the ribbed side of the Rubber (soft) Washer against the hole inside the trough/tank. Insert the Long Tail Adaptor through the washer & inlet hole in the trough/tank wall.

On the outside, place the Poly (hard) Washer on the Long Tail Adaptor with the ribs facing the trough/tank wall. Thread on Adaptor Nut and tighten firmly. Do not over tighten.

Screw the Fast~Flo Float on to the Brass Arm, do not bend Brass Arm
 
 
Click to download The Fast~Flo Valve assembly instructions